How to Test Refrigerator Compressor Windings Using a Multimeter?
Testing refrigerator compressor windings is one of the most reliable ways to determine if a compressor’s electric motor has suffered an internal failure (such as an open circuit, shorted turns, or a ground fault).
If your compressor is clicking, humming without starting, or tripping your home’s circuit breaker, perform these checks before condemning the unit.
Safety First & Preparation
- Unplug the Refrigerator: Completely disconnect power from the wall outlet.
- Access the Compressor: Remove the rear lower access panel of the refrigerator.
- Remove Starting Components: Pull off the protective plastic cover, disconnect the wires, and unplug the PTC start relay and overload protector directly from the 3 terminal pins on the compressor.
- Inspect the Pins: Ensure the 3 copper or brass pins are clean and free of corrosion or burnt residue.
Understanding the 3 Terminal Pins
The compressor motor contains two internal wire coils: the Start Winding (used to kick-start the rotor) and the Run Winding (used during continuous operation). These two coils share a common connection point inside the housing, giving you three exposed terminal pins arranged in a triangle:
- C: Common
- S: Start
- R: Run
[ C ] (Common)
/ \
/ \
[ S ]-------[ R ]
(Start) (Run)
Step-by-Step Multimeter Testing Procedure
Set your digital multimeter to measure Resistance in Ohms (Ω) (or set it to the lowest range, e.g., 200Ω).
[ STEP 1 ] [ STEP 2 ] [ STEP 3 ]
Check Continuity Measure Individual Test Ground Fault
(Open Loop) Resistances (Pin to Frame)
────────────────── ────────────────── ──────────────────
Measure all 3 pairs S-to-C + R-to-C Probe each pin to
(C-S, C-R, S-R). MUST EQUAL S-to-R. bare metal casing.
Any "OL" = Dead Formula: $R_{SC} + Must show "OL". Any
compressor. R_{RC} = R_{SR}$ reading = Shorted.
Test 1: Check Winding Continuity (Open Circuit Test)
Measure resistance across all three pin combinations:
- Common (C) to Start (S)
- Common (C) to Run (R)
- Start (S) to Run (R)
- Expected Result: You should get a low resistance reading (typically between 2Ω and 30Ω) on all three measurements.
- Failure Condition: If any pair displays “OL” (Open Loop / Infinite Resistance), an internal winding has burnt out and broken continuity. The compressor is dead and must be replaced.
Test 2: Verify Winding Resistance Values (The Addition Rule)
In a healthy single-phase induction compressor motor, the electrical relationship between the windings strictly follows this rule:
Resistance (Start to Run)=Resistance (Common to Start)+Resistance (Common to Run)
- Start Winding (RSC): Higher resistance (thinner wire, more turns). Typically 5Ω to 20Ω.
- Run Winding (RRC): Lower resistance (thicker wire, fewer turns). Typically 2Ω to 10Ω.
- Total Across Both (RSR): Highest resistance (sum of both windings).
Example Reading:
- C to S=12Ω
- C to R=4Ω
- S to R=16Ω (12+4=16)
- Failure Condition: If RSR does not approximately equal RSC+RRC, or if two pins show an abnormally low reading (e.g., 0.2Ω), there is an internal short circuit between the winding turns.
Test 3: Ground Fault Test (Short to Ground)
Even if the windings read correct resistance, an internal wire may have melted or broken, touching the metal compressor shell.
- Switch your multimeter to Continuity Mode (Beep) or high Ohms (MΩ).
- Scrape away paint or rust on a bare copper pipe or the bare metal housing of the compressor to ensure a clean ground connection.
- Place one probe firmly on the bare metal ground point.
- Touch the second probe to Pin C, then Pin S, and finally Pin R.
- Expected Result: The meter must show “OL” (Infinite Resistance) for all three pins, and no beep should sound.
- Failure Condition: If the meter beeps, shows zero resistance, or gives a specific resistance reading to ground on any pin, the compressor is shorted to ground (shorted to frame). This will trip your breaker or blow a fuse instantly.
Quick Diagnostic Result Matrix
| Test Passed? | Symptom / Result | Diagnosis | Action |
|---|---|---|---|
| No (“OL” reading) | Broken internal wire on C, S, or R pin | Open Winding | Replace Compressor / Appliance |
| No (Values don’t add up) | Turn-to-turn short circuit inside coils | Shorted Winding | Replace Compressor / Appliance |
| No (Continuity to metal frame) | Live pin touching outer casing | Ground Fault | Replace Compressor / Appliance |
| YES (All 3 tests pass) | Windings are electrically intact | Bad PTC Relay, Capacitor, or Mechanical Seize | Test/Replace Start Relay or check for locked rotor |