How do I test the defrost heater, defrost thermostat, and thermistor on a refrigerator using a multimeter?
Testing these three components with a multimeter allows you to pinpoint the exact failure point in an automatic defrost system without replacing parts unnecessarily.
Safety first: Unplug the refrigerator from the wall power outlet before removing any panel or handling electrical wiring.
1
Prepare the Refrigerator & Access Components
Safety and teardown
- Unplug the refrigerator.
- Access the interior back wall of the freezer compartment by removing the freezer shelves, drawer rails, and rear panel screws.
- Carefully pull the panel forward to expose the evaporator coils, defrost heater, defrost thermostat (bimetal), and thermistor.
2
Test the Defrost Heater
Checking heating element continuity
The defrost heater is a metal tube or glass element running beneath or woven through the evaporator coils.
- Unplug the wiring harness connectors from both ends of the heater. Always disconnect at least one terminal from the circuit to prevent back-feeding false readings.
- Turn your multimeter dial to the Resistance / Ohms (Ω) setting (set to the 200Ω range if manual-ranging).
- Touch one probe to each connector pin of the heater.
- Good Reading: Between 15 Ω and 120 Ω (depending on wattage). This confirms an intact continuous heating circuit.
- Bad Reading: O.L (Open Line/Infinite Resistance) or a reading above 1,000Ω. An O.L reading indicates a broken heater element that needs replacement.
3
Test the Defrost Thermostat (Bimetal Switch)
Temperature-dependent continuity test
The defrost thermostat is a clip-on metal disk snapped directly onto the top or side of the evaporator tube. It functions as a temperature-sensitive switch: open when warm, closed when cold.
- Disconnect the thermostat’s wiring connector.
- Warm Test (At Room Temp): Place multimeter probes on the two leads. It should read O.L (Open) because it prevents the heater from activating when the freezer is warm.
- Cold Test (In-Circuit/Submerged): If the thermostat was just pulled off frost-covered coils (below 15°F / -9°C), or after soaking it in an ice bath for 5 minutes, test the leads again.
- Good Reading: Near 0 Ω (closed circuit/continuity) when cold; O.L when warm.
- Bad Reading: O.L even when frozen solid, or showing resistance values (e.g., 50Ω) instead of a clean open/closed state.
4
Test the Defrost / Temperature Thermistor
Checking temperature-variable resistance
The thermistor is a small plastic-encapsulated sensor. Unlike the bi-metal switch, its resistance changes continuously as the temperature changes (typically an NTC thermistor: higher resistance at lower temperatures).
- Unplug the thermistor harness connector.
- Turn multimeter to the 20k Ω range (or Auto-Ranging Ohms).
- Measure the resistance across the thermistor leads at room temperature (~70°F / 21°C), then place it in a glass of ice water (32°F / 0°C) for a few minutes and test again.
- Good Reading:
- At 70°F (21°C): ~2,000 Ω to 10,000 Ω (2k$\Omega$–10k$\Omega$, brand dependent).
- At 32°F (0°C): Resistance should significantly increase (typically climbing to around 8,000 Ω to 30,000 Ω).
- Bad Reading: Displays O.L, 0 Ω (short circuit), or a static reading that does not change at all when cooled down.
Component Reference Table
| Component | Test Mode | Good Reading (Cold) | Good Reading (Warm / Room Temp) | Failure Sign |
|---|---|---|---|---|
| Defrost Heater | Resistance (Ω) | 15 Ω – 120 Ω | 15 Ω – 120 Ω | Open circuit (O.L) |
| Defrost Thermostat | Continuity / Ω | ~0 Ω (Closed) | O.L (Open) | Always O.L (stuck open) |
| Thermistor | Resistance (k$\Omega$) | ~8k Ω – 30k Ω | ~2k Ω – 10k Ω | O.L, 0 Ω, or fixed value |