Refrigerator fault and its solution

Refrigerator problems usually stem from dirty condenser coils, worn door gaskets, or faulty electrical sensors.

FaultLikely CauseSolution
Not cooling enoughDirty condenser coils, failing door gasket, or blocked air vents inside.Clean coils behind or under the fridge; check door rubber seal with a dollar bill; unblock air vents inside.
Running continuouslyTemperature set too low, dirty coils, or defrost thermostat failure.Set fridge temp to 37°F–40°F (3°C–4°C); clean coils; test defrost thermostat for continuity.
Water leaking on the floorClogged defrost drain line or damaged water supply line.Flush the drain tube inside the back freezer wall with warm water; inspect rear water inlet valves.
Frost buildup in freezerDamaged door seal letting in moist air, or failing defrost heater.Inspect and replace worn door gasket; test defrost heater and timer with a multimeter.
Loud clicking or buzzingDust-clogged condenser fan blade or a faulty compressor starter relay.Clear debris around fan blades behind lower panel; replace start relay plug attached to compressor.
Ice maker stopped workingFrozen supply tube, clogged water filter, or defective water valve.Replace water filter; thaw frozen water inlet tube with warm air; test inlet solenoid valve.

Always unplug the appliance before cleaning coils, inspecting wiring, or replacing electrical parts.